Aluminum Oxidation Wastewater Test Report

HOME    Solutions    Aluminum Oxidation Wastewater Test Report

Test Process

1. Take 60ml wastewater, dose 0.2ml undiluted BWD-01 water decoloring agent, stir evenly

2. Add 0.15ml liquid ferric sulfate, stir evenly Correct pH to 7 by alkali

3. Add anionic polyacrylamide, stir slowly until large flocs come up, sludge generate, the effluent became clear

Test Result

The BWD-01 water decoloring agent and ferric sulfate are effective in this wastewater. Note: Ferric sulfate is a must, otherwise the effluent will not be clear

 

 

 

 

 

 

3

 

Created on:2019-09-05 17:47